Published June 2006 | Version v1
Journal article

Behaviour of steam generator tubing in the presence of silicon compounds

Creators

  • 1. Institute for Nuclear Research, Pitesti Mioveni (Romania)

Description

The chemical reactions that take place between the components of concentrated solutions generate an aggressive environment. The presence of this environment and of the tubesheet crevices lead to localized corrosion and the affected tubes cannot ensure effective heat transfer between the fluids of the primary and secondary circuits. Thus, it becomes necessary to understand the corrosion process that occurs on the CANDU steam generator secondary side. The purpose of this paper is the assessment of the corrosion behaviour of the tube material Incoloy 800 at the normal secondary circuit parameters (temperature = 260 C, pressure = 5.1 MPa). The testing environment was demineralized water containing silicon compounds, at a pH = 9.5 regulated with morpholine and cyclohexylamine. The paper presents the results of metallographic, electronic microscopy and X-ray diffraction examinations, as well as the results of electrochemical measurements. (orig.)

Additional details

Publishing Information

Journal Title
Power Plant Chemistry
Journal Volume
8
Journal Issue
6
Journal Page Range
p. 361-369
ISSN
1438-5325