Published November 2017 | Version v1
Journal article

Diagnostic accuracy of surface coil MRI in assessing cartilaginous invasion in laryngeal tumours. Do we need contrast-agent administration?

  • 1. Division of Radiology, National Center of Oncological Hadrontherapy (CNAO Foundation), Pavia (Italy)
  • 2. Universita degli Studi di Pavia, Department of Clinical-Surgical Diagnostic and Pediatric Sciences, Pavia (Italy)
  • 3. Universita degli Studi di Milano, Postgraduation School in Radiodiagnostics, Milan (Italy)
  • 4. Division of Radiology, Poliambulanza Hospital, Brescia (Italy)
  • 5. European Institute of Oncology, Division of Radiology, Milan (Italy)
  • 6. European Institute of Oncology, Division of Epidemiology and Biostatistics, Milan (Italy)
  • 7. European Institute of Oncology, Division of Head and Neck Surgery, Milan (Italy)
  • 8. European Institute of Oncology, Division of Pathology, Milan (Italy)
  • 9. Universita degli Studi di Milano, Oncology and Haematology/Oncology Department, Milan (Italy)

Description

To assess the diagnostic accuracy of MRI performed using surface coils, with and without contrast medium, in predicting thyroid and cricoid cartilage infiltration in laryngeal tumours, and to investigate whether the radiologist's experience influences diagnostic accuracy. We retrospectively enrolled patients with biopsy-proven laryngeal cancer who had undergone preoperative staging MRI and open surgery. Two radiologists with different experience (senior vs. junior) reviewed the MR images without (session A1) and with contrast medium (session A2) separately. We calculated the accuracy of MRI with and without contrast medium in detecting infiltration of the thyroid and cricoid cartilages. Interobserver agreement was calculated by Cohen's Kappa (k). Forty-two patients were enrolled, for a total of 62 cartilages. In session A1 the senior and junior radiologists showed an accuracy of 85% and 71%, respectively, with k = 0.53 (0.33-0.72). In session A2 the senior and junior radiologists showed an accuracy of 84% and 77%, respectively, with k = 0.68 (0.49-0.86). Staging of laryngeal tumours with surface coil MRI showed good diagnostic accuracy in assessing cartilaginous infiltration. We observed similar values of diagnostic accuracy for the analysis performed with and without contrast medium for the senior radiologist. (orig.)

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00330-017-4840-x

Additional details

Identifiers

Publishing Information

Journal Title
European Radiology
Journal Volume
27
Journal Issue
11
Journal Page Range
p. 4690-4698
ISSN
0938-7994
CODEN
EURAE3