Comparative reviews of diagnostic test accuracy in imaging research: evaluation of current practices
Creators
- 1. University of Ottawa, Department of Radiology-Faculty of Medicine (Canada)
- 2. University of Amsterdam, Amsterdam UMC, Clinical Epidemiology, Biostatistics and Bioinformatics, Amsterdam Public Health (Netherlands)
- 3. Academic Medical Center (Netherlands)
- 4. University of Ottawa, Clinical Epidemiology Program, Ottawa Hospital Research Institute, School of Epidemiology and Public Health (Canada)
- 5. McMaster University (Canada)
- 6. University of Ottawa, Faculty of Medicine (Canada)
- 7. University of Birmingham, Test Evaluation Research Group, Institute of Applied Health Research (United Kingdom)
- 8. Ottawa Hospital Research Institute, Department of Radiology, University of Ottawa, Clinical Epidemiology Program (Canada)
Description
Purpose
The purpose of this methodological review was to determine the extent to which comparative imaging systematic reviews of diagnostic test accuracy (DTA) use primary studies with comparative or non-comparative designs.Methods
MEDLINE was used to identify DTA systematic reviews published in imaging journals between January 2000 and May 2018. Inclusion criteria: systematic reviews comparing at least two index tests (one of which was imaging-based); review characteristics were extracted. Study design and other characteristics of primary studies included in the systematic reviews were evaluated.
Results
One hundred three comparative imaging reviews were included; 11 (11%) included only comparative studies, 12 (11%) included only non-comparative primary studies, and 80 (78%) included both comparative and non-comparative primary studies. For reviews containing both comparative and non-comparative primary studies, the median proportion of non-comparative primary studies was 81% (IQR 57–90%). Of 92 reviews that included non-comparative primary studies, 86% did not recognize this as a limitation. Furthermore, among 4182 primary studies, 3438 (82%) were non-comparative and 744 (18%) were comparative in design.
Conclusion
Most primary studies included in comparative imaging reviews are non-comparative in design and awareness of the risk of bias associated with this is low. This may lead to incorrect conclusions about the relative accuracy of diagnostic tests and be counter-productive for informing guidelines and funding decisions about imaging tests.
Key Points
• Few comparative accuracy imaging reviews include only primary studies with optimal comparative study designs. Among the rest, few recognize the risk of bias conferred from inclusion of primary studies with non-comparative designs.
• The demand for accurate comparative accuracy data combined with minimal awareness of valid comparative study designs may lead to counter-productive research and inadequately supported clinical decisions for diagnostic tests.
• Using comparative accuracy imaging reviews with a high risk of bias to inform guidelines and funding decisions may have detrimental impacts on patient care.
Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 29
- Journal Issue
- 10
- Journal Page Range
- p. 5386-5394
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 54094625
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; HAZARDS; PATIENTS; RECOMMENDATIONS
- Descriptors DEC
- DIAGNOSTIC TECHNIQUES; MEDICINE; NUCLEAR MEDICINE; RADIOLOGY
Optional Information
- Copyright
- Copyright (c) 2019 European Society of Radiology