Published July 8, 1981 | Version v1
Report Restricted

Shutdown heat removal: safety water tests

Description

This specification establishes the requirements to design the SAFETY WATER TESTS to be constructed in the Hydraulic Test Facility (HTF) at the GE San Jose site. The test is an 1/8th scale model of a large loop type breeder reactor or a 1/14th scale model of a large pool type breeder reactor and uses water as the test fluid. It simulates a breeder reactor system with a 0.5 MW heated core with an upper and a lower plenum, a primary loop with 300 gpm flow rate and four auxiliary cooling systems (DRACS) that are to be immersed in the upper plenum and connected to the inlet plenum through a check valve

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01 as DE82008064.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Augmented title (English)
LMFBR

Publishing Information

Imprint Pagination
32 p.
Report number
DOE/SF/71032--T47