Handling of incidents in the clinical application of ionizing radiation in diagnostic and interventional radiology. A multi-center study

  • 1. Institute of Medical Physics, Klinikum Nürnberg, Paracelsus Medical University (Germany)
  • 2. Institute for Diagnostic and Interventional Radiology, University Medical Center Göttingen (Germany)
  • 3. Institute for Diagnostic Radiology and Nuclear medicine, Braunschweig Municipal Hospital (Germany)
  • 4. Medizinphysik-Experten für sonstige Einrichtungen, Charite University Hospital Berlin (Germany)
  • 5. External and Internal Dosimetry, Biokinetics, Federal Office for Radiation Protection Neuherberg (Germany)

Description

According to the German legislation and regulation of radiation protection, i. e. Strahlenschutzgesetz und Strahlenschutzverordnung (StrlSchG and StrlSchV), which came into force on 31st December 2018, significant unintended or accidential exposures have to be reported to the competent authority. Furthermore, facilities have to implement measures to prevent and to recognize unintended or accidental exposures as well as to reduce their consequences. We developed a process to register incidents and tested its application in the framework of a multi-center-study. Materials and Methods Over a period of 12 months, 16 institutions for x-ray diagnostics and interventions, documented their incidents. Documentation of the incidents was conducted using the software CIRSrad, which was developed, released for testing purposes and implemented in the frame of the study. Reporting criteria of the project were selected to be more sensitive compared to the legal criteria specifying "significant incidents". Reported incidents were evaluated after four, eight, and twelve months. Finally, all participating institutions were interviewed on their experience with the software and the correlated effort. Results The rate of reported incidents varied between institutions as well as between modalities. The majority of incidents were reported in conventional x-ray imaging, followed by computed tomography and therapeutic interventions. Incidents were attributed to several different causes, amongst others to the technical setup and patient positioning (19 %) and patient movement or insufficient cooperativeness of the patient (18 %). Most incidents were below corresponding thresholds stated in StrlSchV. The workload for documenting the incidents was rated as appropriate. Conclusion It is possible to monitor and handle incidents complient with legal requirements with an acceptable effort. The number of reported incidents can be increased by frequent trainings on the detection and the processing workflow, on the software and legal regulation as well as by a transparent error handling within the institution.

Availability note (English)

Available from: http://dx.doi.org/10.1055/a-1665-6988

Additional details

Additional titles

Original title (German)
Umgang mit unbeabsichtigten Expositionen bei medizinischen Anwendungen ionisierender Strahlung in der Röntgendiagnostik und interventionellen Radiologie. Eine Multi-Center-Studie

Identifiers

Publishing Information

Journal Title
RoeFo - Fortschritte auf dem Gebiet der Roentgenstrahlen und der bildgebenden Verfahren
Journal Volume
194
Journal Issue
4
Journal Page Range
p. 400-408
ISSN
1438-9029
CODEN
RFGNDO