Published February 1, 1992 | Version v1
Journal article

The half-life of 192Ir

  • 1. National Physical Lab. (NPL), Teddington (United Kingdom)
  • 2. CEC-JRC, Central Bureau for Nuclear Measurements (CBNM), Geel (Belgium)

Description

The current interest in the use of 192Ir for brachytherapy prompted a re-evaluation of existing half-life values. Using the evaluation criteria adopted in a recent IAEA-Coordinated Research Programme, it was determined that the uncertainty in the half-life obtained by evaluating published data spanning the last 20 years is too large. Further measurements of the half-life have been carried out using high-pressure re-entrant ionization chambers. The results of these latest measurements are presented together with a re-evaluation of the half-life using the IAEA-CRP criteria. The recommended half-life of 192Ir is 73.830±0.018 d. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A
Journal Volume
312
Journal Issue
1/2
Series
Nucl. Instrum. Methods Phys. Res., Sect. A.
Journal Page Range
346-348
ISSN
0168-9002
CODEN
NIMAE

Conference

Title
Biennial meeting of the International Committee for Radionuclide Metrology (ICRM) including the international symposium on radionuclide metrology and its applications.
Dates
27-31 May 1991.
Place
Madrid (Spain).