Description

Highlights: • Attenuation in VVER-1000 was determined. • Comparison of TORT and MCNP calculations results with LR-0 measurements. • Usability of LR-0 results to VVER-1000 dosimetry. - Abstract: Evaluation of neutron fluence in a reactor pressure vessel (RPV) together with surveillance specimen programs for RPV materials are one of the most important parts of in-service inspection programs that are necessary for realistic and reliable assessment of RPV residual lifetime. This paper covers transport of neutrons through the RPV of a VVER-1000 nuclear reactor. This problem is of increased importance as it concerns issues around VVER NPP life extension. With regards to the construction (reduced thickness of the lateral reflector), this issue plays greater role in VVER reactors than in Western types of PWR reactors. RPV material degradation depends mainly on neutron flux and spectra. Both quantities can be calculated or measured. This paper compares MCNP calculations and measurements on zero-power experimental reactor LR-0 with TORT calculations for VVER-1000. The goal is to find a reasonable method for precise estimation of neutron fluence and attenuation factor through the RPV. The calculations were performed with MCNP stochastic code and TORT deterministic transport code. The measurements were performed in a VVER-1000 mock-up placed in reactor LR-0 (Research Center Řež).

Availability note (English)

Available from http://dx.doi.org/10.1016/j.anucene.2016.07.027

Additional details

Identifiers

DOI
10.1016/j.anucene.2016.07.027;
PII
S0306-4549(16)30588-6;

Publishing Information

Journal Title
Annals of Nuclear Energy (Oxford)
Journal Volume
98
Journal Page Range
p. 157-165
ISSN
0306-4549
CODEN
ANENDJ

Optional Information

Copyright
Copyright (c) 2016 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.