A Simple DVH Generation Technique for Various Radiotherapy Treatment Planning Systems for an Independent Information System
- 1. Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)
Description
In recent years, the use of a picture archiving and communication system (PACS) for radiation therapy has become the norm in hospital environments and has been suggested for collecting and managing data using Digital Imaging and Communication in Medicine (DICOM) objects from different treatment planning systems (TPSs). However, some TPSs do not provide the ability to export the dose-volume histogram (DVH) in text or other format. In addition, plan review systems for various TPSs often allow DVH recalculations with different algorithms. These algorithms result in inevitable discrepancies between the values obtained with the recalculation and those obtained with TPS itself. The purpose of this study was to develop a simple method for generating reproducible DVH values by using the TPSs. Treatment planning information, including structures and delivered dose, was exported in the DICOM format from the Eclipse v8.9 or the Pinnacle v9.6 planning systems. The supersampling and trilinear interpolation methods were employed to calculate the DVH data from 35 treatment plans. The discrepancies between the DVHs extracted from each TPS and those extracted by using the proposed calculation method were evaluated with respect to the supersampling ratio. The volume, minimum dose, maximum dose, and mean dose were compared. The variations in DVHs from multiple TPSs were compared by using the MIM software v6.1, which is a commercially available treatment planning comparison tool. The overall comparisons of the volume, minimum dose, maximum dose, and mean dose showed that the proposed method generated relatively smaller discrepancies compared with TPS than the MIM software did compare with the TPS. As the structure volume decreased, the overall percent difference increased. The largest difference was observed in small organs such as the eye ball, eye lens, and optic nerve which had volume below 10 cc. A simple and useful technique was developed to generate a DVH with an acceptable error from a proprietary TPS. This study provides a convenient and common framework that will allow the use of a single well-managed storage solution for an independent information system.
Additional details
Publishing Information
- Journal Title
- Journal of the Korean Physical Society
- Journal Volume
- 67
- Journal Issue
- 1
- Series
- 18 refs, 2 figs, 4 tabs
- Journal Page Range
- p. 254-259
- ISSN
- 0374-4884
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 49069578
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ALGORITHMS; COMMUNICATIONS; COMPUTER CALCULATIONS; INFORMATION SYSTEMS; NERVES; PLANNING; RADIATION DOSES; RADIOTHERAPY
- Descriptors DEC
- DOSES; MATHEMATICAL LOGIC; MEDICINE; NERVOUS SYSTEM; NUCLEAR MEDICINE; RADIOLOGY; THERAPY