Published January 2005 | Version v1
Journal article

Experimental investigations of the effect of the pipe diameter and heating nonuniformity on the appearance of the heat transfer crisis in steam-generating pipes

  • 1. OAO NPO TsKTI, Sankt-Peterburg (Russian Federation)

Description

The aim of the paper is to generalize the results of the efforts to investigate into effect of a steam-generating pipe diameter and of nonuniform heating (NH) along its perimeter on heat transfer crisis in the mentioned pipes. One makes a conclusion that extending of pipe diameter results in decrease of critical steam contents and heat loads. Perimetric NH affects flow hydrodynamics and increases heat loads under which crisis of heat transfer occurs

Abstract (Russian)

Цель работы - обобщение результатов исследований влияния диаметра парогенерирующей трубы и неравномерности обогрева (НО) по ее периметру на кризис теплоотдачи в этих трубах. Сделан вывод, что увеличение диаметра трубы приводит к уменьшению критических паросодержаний и тепловых нагрузок. Периметрическая НО влияет на гидродинамику потока и увеличивает тепловые нагрузки, при которых реализуется кризис теплоотдачи

Additional details

Additional titles

Original title (Russian)
Экспериментальное исследование влияния диаметра трубы и неравномерности обогрева по ее периметру на условия возникновения кризиса теплоотдачи в парообразующих трубах

Publishing Information

Journal Title
Teploehnergetika
Journal Issue
no.1
Journal Page Range
p. 64-70
ISSN
0040-3636
CODEN
TPLOA5

Optional Information

Notes
22 refs., 5 figs.