Portable instrumentation for processing information from selected personnel neutron dosimetry detectors
Description
The application of experimental, real-time neutron detectors to measure neutron dose equivalent is discussed. Emphasis is on interfacing the detectors to microcomputer-based portable instruments. This consists of selecting the appropriate neutron detector, determining its operating characteristics and the information it can provide, interfacing this information with a data storage bank, manipulating the data to obtain the neutron dose equivalent, and then providing a read-out in a useful format
Additional details
Publishing Information
- Imprint Title
- Eighth DOE workshop on personnel neutron dosimetry
- Journal Page Range
- p. 43-45.
- Report number
- PNL-SA--9950
Conference
- Title
- 8. DOE workshop on personnel neutron dosimetry.
- Dates
- 18 - 19 Jun 1981.
- Place
- Louisville, KY (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14748730
- Subject category
- S73: NUCLEAR PHYSICS AND RADIATION PHYSICS; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DATA PROCESSING; DOSE EQUIVALENTS; MICROPROCESSORS; NEUTRON DETECTORS; NEUTRON DOSIMETRY; PERSONNEL DOSIMETRY; RADIATION DOSES; SPECIFICATIONS
- Descriptors DEC
- DOSIMETRY; ELECTRONIC CIRCUITS; MEASURING INSTRUMENTS; MICROELECTRONIC CIRCUITS; RADIATION DETECTORS