Allowable spent LWR fuel storage temperatures in inert gases, nitrogen, and air

Description

Spent fuel in inert dry storage is now a reality in the US; recommended maximum temperature-time conditions are specified in an IBM PC-compatible code. However, spent fuel cannot yet be stored in air because the data and theory needed for predicting allowable temperatures are still being developed. Tests to determine the behavior of spent UO2 fragments and breached rod specimens in air are providing data that will be used to determine the temperatures that can be allowed for fuel stored in air. 13 refs., 5 figs

Availability note (English)

MF available from INIS under the Report Number; NTIS, PC A03/MF A01 as DE90006122; OSTI; INIS; US Govt. Printing Office Dep.