MR augmented cardiopulmonary exercise testing—a novel approach to assessing cardiovascular function
Creators
- 1. Institute of Cardiovascular Science, University College London, Centre for Cardiovascular Imaging London (United Kingdom)
- 2. The Heart Hospital, University College London Hospital Foundation Trust, London. W1G 8PH. UK (United Kingdom)
Description
The purposes of this study were: (1) to evaluate feasibility and acceptability of MRI augmented cardiopulmonary exercise testing (MR-CPET) in healthy adults and (2) to test whether peak values obtained at conventional and MR-CPET correlate and to demonstrate variation in peak oxygen consumption (VO2) relates to both peak cardiac output (CO) and peak oxygen extraction (ΔcO2). Seventeen healthy adults underwent CPET and MR-CPET using an MR compatible ergometer and CPET system customised for MR use. Continuous aortic flow measurement used a validated UNFOLD-SENSE spiral phase contrast magnetic resonance (PCMR) sequence.Fifteen of 17 volunteers completed exercise; exclusions were due to claustrophobia and inability to effectively master exercise technique. Measures of acceptability were lower but still satisfactory for MR-CPET.There were strong correlations between conventional and MR-CPET for peak VO2 (r = 0.94, p < 0.001); VCO2 (r = 0.87, p < 0.001) and VE (r = 0.88, p < 0.001).Multiple linear regression analysis demonstrated peak CO and ΔcO2 were independent predictors of peak VO2 measured during MR-CPET (β = 0.73 and 0.38 p < 0.0001) and conventional CPET (β = 0.78, 0.28 p < 0.0001).MR-CPET is feasible, acceptable and demonstrates physiology not apparent with conventional CPET. MR-CPET allows differentiation of the contributions of CO and ΔcO2 to variation in peak VO2. We believe that this will be useful in understanding the origin of reduced exercise capacity in cardiac disease. (note)
Availability note (English)
Available from http://dx.doi.org/10.1088/0967-3334/36/5/N85Additional details
Identifiers
Publishing Information
- Journal Title
- Physiological Measurement (Print)
- Journal Volume
- 36
- Journal Issue
- 5
- Journal Page Range
- p. N85-N94
- ISSN
- 0967-3334
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 48000772
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S60: APPLIED LIFE SCIENCES;
- Descriptors DEI
- ADULTS; BLOOD CIRCULATION; CONSUMPTION RATES; EXERCISE; EXTRACTION; MAGNETIC RESONANCE; NMR IMAGING; OXYGEN; PEAKS; TESTING
- Descriptors DEC
- AGE GROUPS; DIAGNOSTIC TECHNIQUES; ELEMENTS; NONMETALS; RESONANCE; SEPARATION PROCESSES