Published August 1988 | Version v1
Report

Crack-opening area calculations for circumferential through-wall pipe cracks

Description

This report describes the estimation schemes for crack opening displacement (COD) of a circumferential through-wall crack, then compares the COD predictions with pipe experimental data. Accurate predictions for COD are required to reliably predict the leak rate through a crack in leak-before-break applications

Availability note (English)

Research Reports Center, Box 50490, Palo Alto, CA 94303.

Additional details

Publishing Information

Imprint Pagination
127 p.
Report number
EPRI-NP--5959-SR

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
20019118
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
ALGORITHMS; CRACK PROPAGATION; CRACKS; EVALUATION; FRACTURES; NUCLEAR POWER PLANTS; PIPES; REACTOR COMPONENTS; REACTOR COOLING SYSTEMS; REACTOR MATERIALS; RELIABILITY; STRAINS; STRESSES
Descriptors DEC
COOLING SYSTEMS; FAILURES; MATERIALS; NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS