Published March 26, 1999 | Version v1
Report Open

The RHIC Injection System

Description

The RHIC injection system has to transport beam from the AGS-to-RHIC transfer line onto the closed orbits of the RHIC Blue and Yellow rings. This task can be divided into three problems. First, the beam has to be injected into either ring. Second, once injected the beam needs to be transported around the ring for one turn. Third, the orbit must be closed and coherent beam oscillations around the closed orbit should be minimized. They describe their solutions for these problems and report on system tests conducted during the RHIC Sextant test performed in 1997. The system will be fully commissioned in 1999.

Files

36010717.pdf

Files (406.6 kB)

Name Size Download all
md5:f430103fb8332d7b676337fb85a81e9e
406.6 kB Preview Download

System files (13.1 kB)

Name Size Download all

Additional details

Publishing Information

Imprint Pagination
5 p.
Report number
BNL--66006

Conference

Title
1999 Particle Accelerator Conference
Dates
29 Mar - 2 Apr 1999
Place
New York, NY (United States)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
36010717
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ACCELERATORS; BEAM INJECTION; BEAM TRANSPORT; OSCILLATIONS; STORAGE RINGS

Optional Information

Contract/Grant/Project number
KB0202000; AC02-98CH10886
Funding organization
USDOE Office of Energy Research ER (United States)