A systematic comparison of two pulse sequences for edema assessment in MR-mammography
- 1. Institute of Diagnostic and Interventional Radiology, Friedrich-Schiller-University Jena, Erlanger Allee 101, D-07740 Jena (Germany)
- 2. Institute of Pathology, Friedrich-Schiller-University Jena, Ziegelmühlenweg 1, D-07740 Jena (Germany)
- 3. Clinic of Gynecology, Friedrich-Schiller-University Jena, Bachstr. 18, D-07740 Jena (Germany)
Description
Objective: Perifocal edema, defined as high T2w signal intensity around an enhancing lesion has been described as a specific feature of malignancy. In clinical MR-mammography (MRM), both fatsat and non-fatsat T2w sequences are available. However, there is no consensus on which technique should be used for edema assessment. Consequently, this investigation was performed to compare two commonly used pulse sequences for edema assessment in MRM. Materials and methods: 321 consecutive patients from a 22 month period were included in this investigation. Further selection criteria were histopathological verification of enhancing lesions and absence of presurgical chemotherapy or biopsy, resulting in 108 malignant and 107 benign lesions. All underwent MRM according to international guidelines including a non-fatsat T2w-TSE sequence (TR/TE: 8900/207 ms) and a short tau inversion recovery fatsat sequence (STIR, TR/TE: 8420/70 ms). All images were acquired in the same orientation (axial) and slice thickness. Two experienced radiologists in consensus rated presence of perifocal edema according to an ordinal scale: 0 = not present, 1 = little, 2 = intermediate, and 3 = distinct. Data analysis was performed using crosstabs and Visual Grading Characteristics (VGC) analysis. Results: Overall sensitivity/specificity was calculated with 53.7%/94.4% (T2w-TSE) and 52.8%/95.3% (STIR). VGC revealed an area under the VGC curve of 0.502 (standard error 0.026), P = 0.814. Conclusion: Perifocal edema is a specific feature of malignancy with moderate sensitivity. VGC analysis did not reveal significant differences between both pulse sequences analysed. Consequently, both T2w-TSE and STIR images are suitable for assessment of perifocal edema.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ejrad.2011.03.001Additional details
Identifiers
- DOI
- 10.1016/j.ejrad.2011.03.001;
- PII
- S0720-048X(11)00252-X;
Publishing Information
- Journal Title
- European Journal of Radiology
- Journal Volume
- 81
- Journal Issue
- 7
- Journal Page Range
- p. 1500-1503
- ISSN
- 0720-048X
- CODEN
- EJRADR
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 43078739
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; BIOPSY; CHEMOTHERAPY; DATA ANALYSIS; EDEMA; MAMMARY GLANDS; NEOPLASMS; NMR IMAGING; PATIENTS; SENSITIVITY; SPECIFICITY; VERIFICATION
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DISEASES; GLANDS; MEDICINE; NUCLEAR MEDICINE; ORGANS; PATHOLOGICAL CHANGES; RADIOLOGY; SYMPTOMS; THERAPY
Optional Information
- Copyright
- Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.