Published December 2010 | Version v1
Journal article

Practical consequences for the use of a personal dosemeter for fast neutrons at high-energy accelerators based on PADC detectors exposed up to one year

  • 1. Paul Scherrer Institut, 5232 Villigen PSI (Switzerland)

Description

Since 1998, Paul Scherrer Institut has employed the routine use of a personal neutron dosimetry system based on chemically etched PADC (poly allyl diglycol carbonate) detectors and automatic track counting. In 2004, a new concept for individual monitoring at high-energy accelerators was implemented. In this concept the photon dosemeter of a combined photon/neutron dosemeter is evaluated monthly. The neutron dosemeter is only evaluated if the personal photon dose exceeds 2 mSv, or if the exposition period of the neutron dosemeter exceeds one year. Significant consequences for the evaluation of the neutron dosemeter in the dosimetry service were evidenced in the new concept. The wearing period of the neutron dosemeter can range from 1 to 12 months, potentially longer. Therefore, the long-term behavior of background track density and variation of response to Am-Be within 17 months was studied. The effects of 'fading' and 'aging' that influence the response of PADC detectors are determined. The application of an algorithm for neutron dose calculation takes into account long-term behavior and is described. Furthermore, repeated field calibrations were performed at the CERN-EU high-energy reference field (CERF) facility.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radmeas.2010.05.035

Additional details

Identifiers

DOI
10.1016/j.radmeas.2010.05.035;
PII
S1350-4487(10)00175-7;

Publishing Information

Journal Title
Radiation Measurements
Journal Volume
45
Journal Issue
10
Journal Page Range
p. 1557-1559
ISSN
1350-4487
CODEN
RMEAEP

Conference

Title
11. symposium on neutron and ion dosimetry
Acronym
NEUDOS-11
Dates
12-16 Oct 2009
Place
Cape Town (South Africa)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
42082674
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ACCELERATORS; ALGORITHMS; CALIBRATION; DIELECTRIC TRACK DETECTORS; DOSEMETERS; FAST NEUTRONS; NEUTRON DOSIMETRY; PERSONNEL DOSIMETRY; RADIATION DOSES
Descriptors DEC
BARYONS; DOSES; DOSIMETRY; ELEMENTARY PARTICLES; FERMIONS; HADRONS; MATHEMATICAL LOGIC; MEASURING INSTRUMENTS; NEUTRONS; NUCLEONS; RADIATION DETECTORS

Optional Information

Copyright
Copyright (c) 2010 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.