Study on the dose of sperm aries irradiated with 6 MV-X rays in different unit of the patient's body

  • 1. Suzhou Medical College, Suzhou (China)

Description

Purpose: To know the dose of spermary when the patient was radio-treated in head-neck, in thorax, in abdomen with 6MV-X rays, so as to afford experimental dependencies for clinical therapy plan. Methods and Materials ;Put the thermoluminescent dosimeters (TLD) in a tissue-equivalent anthropomorphic phantom's spermary and irradiated with 6 MV-X rays in different unit of the phantom to measure absorbed doses of spermary. Results: Irradiated in the same unit, both of spermaries' doses are not different, while in different unit, the doses of spermary are different. If 1 Gy dose was given in head-neck or in thorax or in abdomen, the doses that spermary absorbed were 0.155 mGy, 0.340 mGy and 32.075 mGy. conclusion: the routine radiotherapy to the tumour in abdomen will damage spermary, the effective method to decrease the dose of spermary is to use screen blanker

Additional details

Publishing Information

Journal Title
Chinese Journal of Radiological Health
Journal Volume
8
Journal Issue
2
Journal Page Range
p. 65-67