Function parametrization applied to capacitive pressure sensor response time
Creators
- 1. Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain)
Description
The response time associated to monitoring pressure sensors, can be estimated from a set of measurements based on power spectral density of pressure fluctuations (PSD). Surveillance and predictive analysis methods are important for achieving a monitoring of pressure sensors. The function parametrization method is an information treatment technique, that allows setting a relationship between a set of measurements, or input (in this case the frequencies associated to the real and complex poles appearing in the PSD), and the physical parameters, or outputs (response time) of a system (the pressure sensors). These measurements and response time proceed from a database, subjected to a statistical analysis which yields a new response time calculation. Consequently, sensor response time can be estimated from the database, without performing any further noise analysis. (author)
Additional details
Publishing Information
- Publisher
- Organisation for Economic Co-Operation and Development.
- Imprint Place
- Paris (France)
- Imprint Title
- SMORN VII
- Imprint Pagination
- (v.2) 578 p.
- Journal Page Range
- p. 310-318.
Conference
- Title
- Symposium on nuclear reactor surveillance and diagnostics.
- Dates
- 19-23 Jun 1995.
- Place
- Avignon (France).
INIS
- Country of Publication
- France
- Country of Input or Organization
- Nuclear Energy Agency of the OECD (NEA)
- INIS RN
- 29016192
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ENERGY SPECTRA; FLUCTUATIONS; PRESSURE GAGES; REACTOR NOISE; SENSITIVITY ANALYSIS; SPECTRAL DENSITY
- Descriptors DEC
- FUNCTIONS; MEASURING INSTRUMENTS; SPECTRA; SPECTRAL FUNCTIONS; VARIATIONS
Optional Information
- Notes