Published 1990 | Version v1
Book

Turbine runback study for the Byron D4 steam generator using RETRAN

  • 1. Commonwealth Edison Co., Chicago, IL (United States)

Description

The reduction of unanticipated reactor trips has been an ongoing effort at Commonwealth Edison. At Byron Station, a particular concern has been the ability of the plant to withstand the loss of a feedwater pump without trip. This paper concerns analytical efforts to quantify and provide recommended plant maneuvers to allow the plant to accommodate the loss of feed pump transient without experiencing a reactor trip. In this paper, the RETRAN computer code is applied to model the loss of a feedwater pump transient. The model is benchmarked against the plant data for an actual event and used to predict performance for additional cases of interest

Additional details

Publishing Information

Publisher
American Society of Mechanical Engineers.
Imprint Place
New York, NY (United States)
ISBN
0-7918-0585-9
Imprint Title
Proceedings of power plant transients---1990
Imprint Pagination
128 p.
Journal Page Range
p. 89-94.

Conference

Title
American Society of Mechanical Engineers (ASME) winter annual meeting.
Dates
25-30 Nov 1990.
Place
Dallas, TX (United States).

Optional Information

Secondary number(s)
CONF-901194--.