Published 1990 | Version v1
Journal article

Determination of circulating blood volume by measurement of indocyanine green dye in hemolysate: A preliminary study

  • 1. Medical School Hannover (West Germany)

Description

In 8 emergency care patients blood volume was determined using Cr51 labelled erythrocytes and indocyanine green (ICG). Prior to measurement of ICG in blood with a spectrophotometer, the blood was hemolyzed with Triton-X. A close correlation of r=0.97 between the Cr51 and the ICGTR-X estimates was found; the ICGTR-X volume was about 3% lower than the Cr51 volume. In five additional in vitro experiments the ICGTR-X method was found to reflect real volumes with an insignificant error of less than 1%. Blood volume determination with ICGTR-X cannot be applied in cases of circulatory failure. ICG should be administered in a dose of 0.5 mg/kg of body weight. For calibration purposes, a two point calibration curve (point 1: point of intersection of x and y axis; point 2: 5 mg ICG/1 of blood) is sufficient. From these preliminary experiments it is concluded that the ICGTR-X method is a rapid and simple technique of blood volume determination with multiple reproducibility which can be carried out in any clinical laboratory

Additional details

Publishing Information

Journal Title
Life Sciences
Journal Volume
46
Journal Issue
9
Series
Life Sci.
Journal Page Range
647-652
ISSN
0024-3205
CODEN