Published May 1980
| Version v1
Journal article
The results of a decade of individual personnel radiation monitoring and comments on the application of working condition B
Description
The results of ten years individual film badge monitoring at the Royal Perth Hospital have shown that the majority of occupationally exposed staff have recorded less than 1 mSv per year or 2% of the annual dose equivalent limit. It is suggested that in this and, in probably many other medical situations, the ICRP recommended level of 15 mSv per year at which individual monitoring need not be performed is too high to be of practical value and that a level of 5mSv may be of greater use
Additional details
Publishing Information
- Journal Title
- Australas. Phys. Eng. Sci. Med.
- Journal Volume
- 3
- Journal Issue
- 3
- Series
- Australas. Phys. Eng. Sci. Med.
- Journal Page Range
- 150-157
- ISSN
- 0158-9938
INIS
- Country of Publication
- Australia
- Country of Input or Organization
- Australia
- INIS RN
- 12596013
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- MEDICAL PERSONNEL; PERSONNEL MONITORING; RADIATION DOSES; RADIATION PROTECTION; RADIOLOGICAL PERSONNEL
- Descriptors DEC
- MONITORING; PERSONNEL; RADIATION MONITORING