Published January 1995 | Version v1
Journal article

A Three-year survey of film badge service performance in Iran

Description

An extensive study was undertaken to investigate on the overall film badge service performance with which occupational radiation exposures are reported in Iran. The study involved the analysis of film badges exposed to x-and gamma rays and beta particles. For test exposures, x-rays between 60 and 140 k vp. Co-60 gamma radiation and Sr-90 beta particles were used. the actual delivered dose equivalents were limited to 0.40-5 mSv which is the range of annual occupational dose reported by many international studies. This study revealed that the reporting on gamma rays, specially for Co-60, was very good. The reports on x-rays were overestimated. The overestimation was considerable at higher k vp's. The results for beta particles were rather poor

Availability note (English)

Available from Atomic Energy Organization of Iran

Additional details

Publishing Information

Journal Title
Iranian Journal of Nuclear Medicine
Journal Issue
no.3
Journal Page Range
p. 19-29
ISSN
1681-2824