Published January 1976 | Version v1
Journal article

A circulation neon purification system for spark chambers

  • 1. Joint Inst. for Nuclear Research, Dubna (USSR)

Description

The neon circulatory purification system described is employed with a great number of spark chambers in operation. The system provides the neon purification at a rate of 800 litres per hour (at a pressure of 0 to 2 mm H2O and maximum diffusion of 10 l/h) as well as composition of the mixture of gases required for the operation of the chambers

Additional details

Additional titles

Original title (Russian)
Циркуляционная система очистки неона для искровых Камер

Publishing Information

Journal Title
Prib. Tekh. Ehksp.
Journal Issue
no.1
Series
Prib. Tekh. Ehksp.

Optional Information

Notes
For English translation see the journal Instrum. Exp. Tech.