Intensity transformer for the ionic current measurement of the CRYEBIS ion source

Description

A high-sensitivity toroidal transformer has been studied and tested to measure in a permanent and non-destructive way a pulsed ion-beam intensity of 1011 to 1012 charges in 500μs equivalent, to 30μA-peak. The low-impedance and high-gain amplifier (106) allows to measure currents from 1μA-to peak

Availability note (English)

MF available from INIS under the Report Number.

Abstract (French)

Un transformateur de haute sensibilite a noyau torique a ete etudie et mis au point pour la mesure permanente et non-destructive de l'intensite d'un faisceau d'ions pulse de 1011 a 1012 charges en 500 μs, soit 30μA-crete. L'amplificateur a basse impedance et de gain eleve (106) permet de mesurer des courants de 1μA-crete

Files

11505944.pdf

Files (139.7 kB)

Name Size Download all
md5:ce7c7629a55adb763f6d357f781bfb03
139.7 kB Preview Download

Additional details

Additional titles

Original title (French)
Transformateur d'intensites pour la mesure du courant ionique de la source d'ions CRYEBIS

Publishing Information

Imprint Pagination
12 p.
Report number
IPNO--78-03

INIS

Country of Publication
France
Country of Input or Organization
France
INIS RN
11505944
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
ION BEAMS; ION SOURCES; MICRO AMP BEAM CURRENTS; TRANSFORMERS
Descriptors DEC
BEAM CURRENTS; BEAMS; CURRENTS; ELECTRICAL EQUIPMENT