Published December 1984
| Version v1
Report
Open
Far-infrared laser scattering in the ACT-I toroidal device
Description
A far-infrared laser scattering diagnostic has been built for the ACT-I toroidal device. The optical system uses a passively stabilized 447-μm CH3I laser. A polyethylene etalon is the beam splitter. The vacuum windows are plastic (TPX), which we found has the vacuum property Q 6.5 x 10-9 torr-liter/sec/cm2. Using paraboloidal and ellipsoidal mirrors for detection optics improves the signal strength and allows a better rf enclosure design for the detector. The diagnostic was tested by scattering from an ion Bernstein wave, a technique which can be used for ion temperature diagnostics
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE85005341.Files
16055703.pdf
Files
(246.5 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:9b94363728704480de56b2b60ed16246
|
246.5 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 15 p.
- Report number
- PPPL--2171
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 16055703
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- BERNSTEIN MODE; FAR INFRARED RADIATION; ION TEMPERATURE; LASER RADIATION; PLASMA DIAGNOSTICS; TOKAMAK DEVICES
- Descriptors DEC
- CLOSED PLASMA DEVICES; ELECTROMAGNETIC RADIATION; INFRARED RADIATION; OSCILLATION MODES; RADIATIONS; THERMONUCLEAR DEVICES