Published June 2008 | Version v1
Miscellaneous

Improvement of internal dose measurement program using a whole body counter at nuclear power plants

  • 1. Korea Electric Power Research Inst., Daejeon (Korea, Republic of)

Description

A whole body counter (WBC) is used in nuclear power plants (NPPs) to identify and measure the radioactivity in the bodies of human beings. In this study, several experiments were conducted to improve the internal dose measurement procedures using a WBC in NPPs. First, back and forth countings using a WBC were carried out to set up the discrimination program between internal and external radioactive contamination in NPPs. Second, experiments on selecting an optimal geometry of the WBC and locating the contaminated area of radionuclides were performed. (author)

Part of:
Proceedings of the fourth international symposium on radiation safety and detection technology

Additional details

Publishing Information

Imprint Title
Proceedings of the fourth international symposium on radiation safety and detection technology
Imprint Pagination
765 p.
Journal Page Range
p. 155-158

Conference

Title
4. international symposium on radiation safety and detection technology
Acronym
ISORD-4
Dates
18-20 Jul 2007
Place
Seoul (Korea, Republic of)

Optional Information

Notes
3 refs., 3 figs.; This record replaces 43093507 Imprint:Published as Supplement 5 (Jun 2008) of Journal of Nuclear Science and Technology. Publication month in colophon is Aug 2008