Published March 1998
| Version v1
Report
Accuracy of helium accumulation fluence monitor for fast reactor dosimetry
Creators
- 1. Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center
Description
A helium (He) accumulation fluence monitor (HAFM) has been developed for fast reactor dosimetry. In order to evaluate the measurement accuracy of neutron fluence by the HAFM method, the HAFMs of enriched boron (B) and beryllium (Be) were irradiated in the Fast Neutron Source Reactor 'YAYOI'. The number of He atoms produced in the HAFMs were measured and compared with the calculated values. As a result of this study, it was confirmed that the neutron fluence could be measured within 5 % by the HAFM method, and that met the required accuracy for fast reactor dosimetry. (author)
Additional details
Publishing Information
- Imprint Title
- Proceedings of the 1997 symposium on nuclear data
- Imprint Pagination
- 372 p.
- Journal Page Range
- p. 144-149
- Report number
- JAERI-Conf--98-003
Conference
- Title
- 1997 symposium on nuclear data
- Dates
- 27-28 Nov 1997
- Place
- Tokai, Ibaraki (Japan)
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 29046811
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BERYLLIUM 9 TARGET; BORON 10 TARGET; BUILDUP; FAST NEUTRONS; FAST REACTORS; HELIUM; NEUTRON DOSIMETRY; NEUTRON FLUENCE; REACTOR MONITORING SYSTEMS
- Descriptors DEC
- BARYONS; DOSIMETRY; ELEMENTARY PARTICLES; ELEMENTS; EPITHERMAL REACTORS; FERMIONS; HADRONS; NEUTRONS; NONMETALS; NUCLEONS; RARE GASES; REACTORS; TARGETS
Optional Information
- Secondary number(s)
- INDC(JPN)--180/U