Published March 1998 | Version v1
Report

Accuracy of helium accumulation fluence monitor for fast reactor dosimetry

  • 1. Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

Description

A helium (He) accumulation fluence monitor (HAFM) has been developed for fast reactor dosimetry. In order to evaluate the measurement accuracy of neutron fluence by the HAFM method, the HAFMs of enriched boron (B) and beryllium (Be) were irradiated in the Fast Neutron Source Reactor 'YAYOI'. The number of He atoms produced in the HAFMs were measured and compared with the calculated values. As a result of this study, it was confirmed that the neutron fluence could be measured within 5 % by the HAFM method, and that met the required accuracy for fast reactor dosimetry. (author)

Part of:
Proceedings of the 1997 symposium on nuclear data

Additional details

Publishing Information

Imprint Title
Proceedings of the 1997 symposium on nuclear data
Imprint Pagination
372 p.
Journal Page Range
p. 144-149
Report number
JAERI-Conf--98-003

Conference

Title
1997 symposium on nuclear data
Dates
27-28 Nov 1997
Place
Tokai, Ibaraki (Japan)

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
29046811
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BERYLLIUM 9 TARGET; BORON 10 TARGET; BUILDUP; FAST NEUTRONS; FAST REACTORS; HELIUM; NEUTRON DOSIMETRY; NEUTRON FLUENCE; REACTOR MONITORING SYSTEMS
Descriptors DEC
BARYONS; DOSIMETRY; ELEMENTARY PARTICLES; ELEMENTS; EPITHERMAL REACTORS; FERMIONS; HADRONS; NEUTRONS; NONMETALS; NUCLEONS; RARE GASES; REACTORS; TARGETS

Optional Information

Secondary number(s)
INDC(JPN)--180/U