Published 1991 | Version v1
Journal article

Holdup data analysis for Portsmouth Building X705

  • 1. Los Alamos National Lab., NM (United States)
  • 2. Martin Marietta Energy Systems, Inc., Piketon, OH (United States)

Description

The Portsmouth Gaseous diffusion Plant's Building X705 contains equipment for recovering uranium from other facility process equipment and materials. Measurements of holdup have been made at 825 locations within the building, including tanks, columns, pipes, and dissolution/leaching process equipment. These measurements have been made by the Applied Nuclear Technology Group of the Portsmouth Gaseous Diffusion Plant. Measuring holdup is strenuous and labor intensive, and it is desirable to reduce manpower requirements while maintaining some knowledge of facility holdup. The Los Alamos Safeguards Systems Group has helped analyze the data for total holdup and its uncertainty and developed a sampling plan to reduce the manpower requirements. This plan provides assurance that the process equipment has been flushed out, allows a statement of the total holdup and its uncertainty, and permits fewer measurements. In this paper the details of the data analysis and the sampling plan and its application to other facilities are discussed

Additional details

Publishing Information

Journal Title
Nuclear Materials Management
Journal Volume
20
Series
Nucl. Mater. Manage.
Journal Page Range
79-82
ISSN
0362-0034
CODEN
NUMMB

Conference

Title
32. Institute of Nuclear Materials Management (INMM) annual meeting.
Dates
28-31 Jul 1991.
Place
New Orleans, LA (United States).

Optional Information

Secondary number(s)
CONF-910774--.