Is a Single Respiratory Correlated 4D-CT Study Sufficient for Evaluation of Breathing Motion?
Creators
- 1. Department of Radiation Oncology, Julius-Maximilians University of Wuerzburg, Wuerzburg (Germany)
Description
Purpose: Respiratory correlated computed tomography has been shown to be effective for evaluation of breathing-induced motion of pulmonary tumors. This study investigated whether a single four-dimensional CT study (4D-CT) is representative and sufficient for treatment planning in stereotactic body radiotherapy (SBRT). Methods and Materials: Four repeated helical 4D-CT studies were acquired every 10 min for 10 patients with 14 pulmonary metastases. Patients remained immobilized in a stereotactic body frame (SBF) for 30 min; abdominal compression was applied to seven patients. Using amplitude based sorting, eight phases equally distributed over the breathing cycle were reconstructed for each 4D-CT study. Tumor position was defined in a total of 406 CT series and variability of breathing motion and mean tumor position were evaluated. Results: Peak-to-peak tumor motion was 9.9 mm ± 6.8 mm (mean ± standard deviation) and 9.0 mm ± 7.4 mm at time point 0 min (t0) and t30, respectively. In one patient with poor pulmonary function, continuous increase of breathing motion from 17.4 mm at t0 to 28.3 mm at t30 was seen. In five and two lesions, respectively, a drift of the mean tumor position greater than 3 mm and 5 mm was observed. A borderline significance was calculated for larger tumor position variability in midventilation phases compared with peak-ventilation phases of the breathing cycle (p = 0.08). Conclusion: Treatment planning based on a single 4D-CT study is reliable for the majority of patients. Increased intrafractional uncertainties were seen for patients with poor pulmonary function and with tumors located in the lower lobe
Additional details
Identifiers
- DOI
- 10.1016/j.ijrobp.2006.11.025;
- PII
- S0360-3016(06)03519-X;
Publishing Information
- Journal Title
- International Journal of Radiation Oncology, Biology and Physics
- Journal Volume
- 67
- Journal Issue
- 5
- Journal Page Range
- p. 1352-1359
- ISSN
- 0360-3016
- CODEN
- IOBPD3
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 38101803
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- AMPLITUDES; CARCINOMAS; COMPRESSION; COMPUTERIZED TOMOGRAPHY; ERRORS; LUNGS; METASTASES; PATIENTS; RESPIRATION
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DISEASES; NEOPLASMS; ORGANS; RESPIRATORY SYSTEM; TOMOGRAPHY