The 222Rn Reference Measurement System developed at ENEA
Creators
- 1. Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti, Centro Ricerche Casaccia, Roma (Italy)
- 2. Institute of Nuclear Physics, Tirana (Albania)
Description
A 222Rn Reference Measurement System was recently developed at ENEA. The system is based on a radon transfer and counting system calibrated by a 226Ra standard liquid solution. The reference counting instrument is a cylindrical electrostatic cell with a Si detector. It is used for the detection of the electrostatically collected 218Po ions produced in the decay of 222Rn. The activity of 222Rn gas in a spherical glass bulb can be measured in the Reference Measurement System by a particular procedure that does not require volume determinations or any assumption of total radon removal from the liquid 226Ra solution. The combined uncertainty estimated for the calibration of 222Rn sources as in a typical gas transfer system is about 1% (one standard deviation). The Reference Measurement System and the operational procedure adopted by ENEA are described together with a short outline of the transfer instrument based on a NaI(Tl) well-type detector used for calibration purposes. (orig.)
Additional details
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 369
- Journal Issue
- 2-3
- Journal Page Range
- p. 445-451.
- ISSN
- 0168-9002
- CODEN
- NIMAER
Conference
- Title
- International symposium on radionuclide metrology and its applications.
- Original Conference Title
- Symposium International sur la Metrologie des Radionucleides et ses Applications
- Dates
- 15-19 May 1995.
- Place
- Paris (France).
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Netherlands
- INIS RN
- 27032151
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ALPHA DECAY; ALPHA DETECTION; CALIBRATION; CALIBRATION STANDARDS; COUNTING RATES; CYLINDRICAL CONFIGURATION; EFFICIENCY; GAMMA DETECTION; ITALIAN ENEA; NAI DETECTORS; POLONIUM IONS; POLONIUM 218; RADIATION MONITORING; RADIUM 226; RADON 222; REACTION PRODUCT TRANSPORT SYSTEMS; SI SEMICONDUCTOR DETECTORS; SOLUTIONS; TRAPS
- Descriptors DEC
- ALPHA DECAY RADIOISOTOPES; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CARBON 14 DECAY RADIOISOTOPES; CHARGED PARTICLE DETECTION; CHARGED PARTICLES; CONFIGURATION; DAYS LIVING RADIOISOTOPES; DECAY; DETECTION; DISPERSIONS; EVEN-EVEN NUCLEI; HEAVY ION DECAY RADIOISOTOPES; HEAVY NUCLEI; HOMOGENEOUS MIXTURES; IONS; ISOTOPES; ITALIAN ORGANIZATIONS; MEASURING INSTRUMENTS; MINUTES LIVING RADIOISOTOPES; MIXTURES; MONITORING; NATIONAL ORGANIZATIONS; NUCLEAR DECAY; NUCLEI; POLONIUM ISOTOPES; RADIATION DETECTION; RADIATION DETECTORS; RADIOISOTOPES; RADIUM ISOTOPES; RADON ISOTOPES; SCINTILLATION COUNTERS; SEMICONDUCTOR DETECTORS; SOLID SCINTILLATION DETECTORS; STANDARDS; YEARS LIVING RADIOISOTOPES