Published July 2008 | Version v1
Journal article

Intrinsic respiratory gating in small-animal CT

  • 1. German Cancer Research Center (DKFZ), Junior Group Molecular Imaging, Department Medical Physics in Radiology, Heidelberg (Germany)
  • 2. German Cancer Research Center (DKFZ), Department of Medical Physics in Radiology, Heidelberg (Germany)
  • 3. German Cancer Research Center (DKFZ), Junior Group Molecular Imaging, Heidelberg (Germany)
  • 4. German Cancer Research Center (DKFZ), Department of Radiology, Heidelberg (Germany)
  • 5. Siemens Medical Solutions, Forchheim (Germany)
  • 6. Massachusetts General Hospital, Department of Radiology, Boston, MA (United States)

Description

Gating in small-animal CT imaging can compensate artefacts caused by physiological motion during scanning. However, all published gating approaches for small animals rely on additional hardware to derive the gating signals. In contrast, in this study a novel method of intrinsic respiratory gating of rodents was developed and tested for mice (n=5), rats (n=5) and rabbits (n=2) in a flat-panel cone-beam CT system. In a consensus read image quality was compared with that of non-gated and retrospective extrinsically gated scans performed using a pneumatic cushion. In comparison to non-gated images, image quality improved significantly using intrinsic and extrinsic gating. Delineation of diaphragm and lung structure improved in all animals. Image quality of intrinsically gated CT was judged to be equivalent to extrinsically gated ones. Additionally 4D datasets were calculated using both gating methods. Values for expiratory, inspiratory and tidal lung volumes determined with the two gating methods were comparable and correlated well with values known from the literature. We could show that intrinsic respiratory gating in rodents makes additional gating hardware and preparatory efforts superfluous. This method improves image quality and allows derivation of functional data. Therefore it bears the potential to find wide applications in small-animal CT imaging. (orig.)

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00330-008-0903-3

Additional details

Identifiers

Publishing Information

Journal Title
European Radiology
Journal Volume
18
Journal Issue
7
Journal Page Range
p. 1375-1384
ISSN
0938-7994
CODEN
EURAE3

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
39077558
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
COMPUTERIZED TOMOGRAPHY; MICE; RABBITS
Descriptors DEC
ANIMALS; DIAGNOSTIC TECHNIQUES; MAMMALS; RODENTS; TOMOGRAPHY; VERTEBRATES