Published January 1, 2004 | Version v1
Journal article

Performance of Nondestructive Radioassay Systems for Nuclear Waste

Description

A statistical analysis of the measurement performance of five mobile nondestructive assay systems currently in use for radioassay of nuclear waste was performed. Actual versus reported isotopic mass composition, reported versus actual measurement uncertainty, detection capability, and low level versus transuranic waste determination were assessed based on measurements of 11 surrogate waste drums. In terms of percent recovery the systems, for the most part, exhibited reasonable capabilities for estimating isotopic quantities in the surrogate waste drums. (By reasonable we mean, for example, that recovery values were in a range of 40% to 160% for most of the configurations tested.) While difference in performance on individual drums was quite large in some cases, nonparametric analysis of variance results for total plutonium and 241Am showed no statistically significant differences in the overall average percent recovery values for the systems evaluated. A similar analysis of the replicate standard deviations indicated significant differences between systems with regard to precision of measurements of total plutonium but not 241Am. The weakest aspect of system performance was the reporting of measurement errors. Reported measurement error values routinely underestimated actual values for certain surrogate waste configurations

Additional details

Publishing Information

Journal Title
Practice Periodical of Hazardous, Toxic, and Radioactive Waste Management
Journal Volume
8
Journal Issue
1
Journal Page Range
p. 7-18
ISSN
1090-025X

Optional Information

Contract/Grant/Project number
AC07-99ID-13727
Notes
doi 10.1061/(ASCE)1090-025X(2004)8:1(7)
Funding organization
US Department of Energy (United States)
Secondary number(s)
INEEL/JOU--02-01226