Published 1987 | Version v1
Book

Effective use of lithium fluoride, TLD-100, at very low radiation doses

  • 1. NASA/Johnson Space Center, Houston, TX (USA)

Description

Two reasons have beren given for reluctance in using lithium fluoride, TLD-100, for measurement of very low radiation doses: inadequate sensitivity, and nonlinearity. The authors examined the selection, handling, annealing, and readout procedures for potential use of this material for low dose applications. Experiments to measure the sensitivity and linearity were conducted and are described. Two annealing techniques were evaluated. Data and associated procedures are presented which demonstrate that, using commercially available detectors and readers, doses significantly less than 1.0 millirad may be measured with reasonable consistency and accuracy

Additional details

Publishing Information

Publisher
American Nuclear Society.
Imprint Place
La Grange Park, IL (USA)
ISBN
0-89448-132-0
Imprint Title
Proceedings of the topical conference on theory and practices in radiation protection and shielding. Volumes 1-2
Journal Page Range
vp.

Conference

Title
Topical conference on theory and practice in radiation protection and shielding.
Dates
22-24 Apr 1987.
Place
Knoxville, TN (USA).