Published 2008 | Version v1
Journal article

Extremity ring dosimetry intercomparison in reference and workplace fields

  • 1. Institut de Tecniques Energetiques, Universitat Politecnica de Catalunya, Diagonal 647, 08028 Barcelona (Spain)
  • 2. Greek Atomic Energy Commission, Ag. Paraskevi 15310 (Greece)
  • 3. Institut de Radioprotection et de Surete Nucleaire, 92262 Fontenay-aux-Roses Cedex (France)
  • 4. Nofer Inst. of Occupational Medicine, St. Teresa Street 8, 90-950 Lodz (Poland)
  • 5. Bundesamt fuer Strahlenschutz, BfS, Koepenicker Allee 120-130, 10312 Berlin (Germany)
  • 6. Institut Universitaire de Radiophysique Appliquee, rue du Grand Pre 1, 1007 Lausanne (Switzerland)
  • 7. Belgian Nuclear Research Centre, Boeretang 200, 2400 Mol (Belgium)
  • 8. CEA LIST Laboratoire National Henri Becquerel, CEA Saclay 91191 Gif sur Yvette Cedex (France)
  • 9. Radiation Protection Dept., Univ. of Brussels and Academic Hospital AZ-VUB, Brussels (Belgium)

Description

An intercomparison of ring dosemeters has been organised with the aim of assessing the technical capabilities of available extremity dosemeters and focusing on their performance at clinical workplaces with potentially high extremity doses. Twenty-four services from 16 countries participated in the intercomparison. The dosemeters were exposed to reference photon ( 137Cs) and beta (147Pm, 85Kr and 90Sr/90Y) fields together with fields representing realistic exposure situations in interventional radiology (direct and scattered radiation) and nuclear medicine ( 99mTc and 18F). It has been found that most dosemeters provided satisfactory measurements of Hp(0.07) for photon radiation, both in reference and realistic fields. However, only four dosemeters fulfilled the established requirements for all radiation qualities. The main difficulties were found for the measurement of low-energy beta radiation. Finally, the results also showed a general under-response of detectors to 18F, which was attributed to the difficulties of the dosimetric systems to measure the positron contribution to the dose. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncn230

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
131
Journal Issue
1
Journal Page Range
p. 67-72
ISSN
0144-8420

Conference

Title
Scientific symposium on Achievements within the CONRAD coordination action (FP6); Winter school on Retrospective dosimetry; Workshop on Dosimetric issues in the medical use of ionizing radiation; EURADOS Annual Meeting 2008 - AM2008
Dates
23-25 Jan 2008
Place
Paris (France)

Optional Information

Notes
21 refs