Published July 26, 1973
| Version v1
Report
Restricted
Zion Nuclear Plant, Unit 1. Abnormal occurrence: a setpoint change which readjusts the gain and bias on the turbine impulse chamber pressure modules was found to be in error
Description
no abstract available
Availability note (English)
MF available from INIS under the Report Number.
Files
Additional details
Additional titles
- Augmented title (English)
- Gain and bias on turbine impulse chamber pressure modules found to be in error
Publishing Information
- Imprint Pagination
- 3 p.
- Report number
- DOCKET-50295--173
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 5106323
- Subject category
- S99: GENERAL AND MISCELLANEOUS; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- PIPES; REACTOR OPERATION; STEAM; ZION-1 REACTOR
- Descriptors DEC
- ENRICHED URANIUM REACTORS; OPERATION; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS