Published February 20, 1975 | Version v1
Report Restricted

Mean time to failure of high temperature thermocouples in irradiation capsules

Description

The results of calculations of the mean time before failure of thermocouples as a function of temperature and neutron flux are presented. These thermocouples were used in the performance of in-reactor tests of the coated particle fuel for use in high-temperture gas-cooled nuclear reactors. The results cover 429 type K chromel-alumel thermocouples tested in an atmosphere of helium and argon gas at temperatures of 300 to 10000C, at fast neutron (E greater than 0.18 MeV) fluxes of 1.44 x 1013 to 6.48 x 1014, for periods up to 6000 hours. (U.S.)

Availability note (English)

MF available from INIS under the Report Number.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
7 p.
Report number
GA-A--13241