Published 1996 | Version v1
Miscellaneous

A study on thoron decay products in the air

  • 1. Physics Dept. Faculty of Science, El-minia Univ., El-Minia (Egypt)

Description

Low pressure Berner cascade impactor technique was used as sampling device to determine the concentration ansd activity size distribution of 212Pb in the open air. The collected activity in each stage of the impactor was measured by a γ spectrometer with 5 x 5 Nal(tl)detector. The activity size distribution of 212Pb was described by one long-normal distribution. The mean AMAD was 345 nm with α9=2.7 o. 4 figs., 3 tabs

Part of:
Proceedings of the third Radiation Physics Conference. Vol. 1

Additional details

Publishing Information

Imprint Place
Cairo (Egypt)
Imprint Title
Proceedings of the third Radiation Physics Conference. Vol. 1
Imprint Pagination
332 p.
Journal Page Range
p. 241-249.
Report number
INIS-EG--005

Conference

Title
3. Radiation Physics Conference.
Dates
13-17 Nov 1996.
Place
Cairo (Egypt).

Optional Information