Published 1996 | Version v1
Journal article

New aspects of environmental monitoring using flat phosphate glass and thermoluminescence dosemeters

  • 1. Forschungszentrum Karlsruhe GmbH Technik und Umwelt (Germany)
  • 2. Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany)

Description

At the Karlsruhe Monitoring Service photoluminescence dosimetry (PLD) systems have been used in environmental monitoring since the middle of the 1960s. Nowadays flat glass dosemeters with a pattern approval by the Physikalisch Technische Bundesanstalt (PTB) and full automatic readout using pulsed UV laser excitation and pre-dose suppression have replaced the old PLD system. The special advantages of glass dosemeters for this application are above all the long-term stability of field and calibration dosemeters and the insensitivity to ambient temperature and humidity. Based on twenty years experience and the recent progress in routine monitoring by introducing new dosimetry systems, the paper discusses actual results of flat glass PLD systems and LiF thermoluminescence dosimetry (TLD) systems, which have been simultaneously used for environmental monitoring. The PLD system with a fading of about 1% is stable without any temperature treatment. Due to the instability of electron traps in TLD-700 and the temperature dependent fading. TLD-700 underestimates the natural radiation background by 5 to 10% depending on seasonal effects, which is demonstrated in a ten years experiment in the environment. The response to cosmic rays found to be 0.91 for PLD and 0.82 for TLD-700, indicates a more pronounced under-response of TLD. Without applying individual calibration factors for each PL dosemeter, the coefficient of variation for the readout at 0.1 mSv is about 10%. Calibration procedures and correction factors are discussed which may improve the consistency of environmental dose results. (Author)

Additional details

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
66
Journal Issue
1-4
Journal Page Range
p. 187-192.
ISSN
0144-8420
CODEN
RPDODE

Conference

Title
11. international conference on solid state dosimetry.
Dates
10-14 Jul 1995.
Place
Budapest (Hungary).

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
28034038
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
AUTOMATION; CALIBRATION; CORRECTIONS; ENVIRONMENT; PHOSPHATE GLASS; RADIATION MONITORING; READOUT SYSTEMS; RPL DOSEMETERS; THERMOLUMINESCENT DOSEMETERS
Descriptors DEC
DOSEMETERS; GLASS; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MONITORING

Optional Information

Secondary number(s)
CONF--950708.