At the Karlsruhe Monitoring Service photoluminescence dosimetry (PLD) systems have been used in environmental monitoring since the middle of the 1960s. Nowadays flat glass dosemeters with a pattern approval by the Physikalisch Technische Bundesanstalt (PTB) and full automatic readout using pulsed UV laser excitation and pre-dose suppression have replaced the old PLD system. The special advantages of glass dosemeters for this application are above all the long-term stability of field and calibration dosemeters and the insensitivity to ambient temperature and humidity. Based on twenty years experience and the recent progress in routine monitoring by introducing new dosimetry systems, the paper discusses actual results of flat glass PLD systems and LiF thermoluminescence dosimetry (TLD) systems, which have been simultaneously used for environmental monitoring. The PLD system with a fading of about 1% is stable without any temperature treatment. Due to the instability of electron traps in TLD-700 and the temperature dependent fading. TLD-700 underestimates the natural radiation background by 5 to 10% depending on seasonal effects, which is demonstrated in a ten years experiment in the environment. The response to cosmic rays found to be 0.91 for PLD and 0.82 for TLD-700, indicates a more pronounced under-response of TLD. Without applying individual calibration factors for each PL dosemeter, the coefficient of variation for the readout at 0.1 mSv is about 10%. Calibration procedures and correction factors are discussed which may improve the consistency of environmental dose results. (Author)
Additional details
Publishing Information
- Journal Title
- Radiation Protection Dosimetry
- Journal Volume
- 66
- Journal Issue
- 1-4
- Journal Page Range
- p. 187-192.
- ISSN
- 0144-8420
- CODEN
- RPDODE
Conference
- Title
- 11. international conference on solid state dosimetry.
- Dates
- 10-14 Jul 1995.
- Place
- Budapest (Hungary).
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 28034038
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- AUTOMATION; CALIBRATION; CORRECTIONS; ENVIRONMENT; PHOSPHATE GLASS; RADIATION MONITORING; READOUT SYSTEMS; RPL DOSEMETERS; THERMOLUMINESCENT DOSEMETERS
- Descriptors DEC
- DOSEMETERS; GLASS; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MONITORING