Published December 2003 | Version v1
Journal article

Determination of single escape and double escape peak efficiency for a HPGe detector

  • 1. Seoul National Univ., Seoul (Korea, Republic of)

Description

The efficiencies of single escape and double escape peaks were calculated by using Monte Carlo method and compared with measured efficiencies. The efficiency was obtained from the area ratio of escape peak to full energy absorption peak and the full energy absorption peak efficiency. For the escape peak interfered with other γ-ray peaks, the net area was obtained by area correction. The GEANT code developed in CERN was used for the Monte Carlo calculation. The calculated efficiencies of the escape peaks agreed with the measurement within 12%

Additional details

Publishing Information

Journal Title
Journal of the Korean Nuclear Society
Journal Volume
35
Journal Issue
6
Series
10 refs, 7 figs, 1 tab
Journal Page Range
p. 523-528
ISSN
0372-7327
CODEN
WJHKAW