Replacement of venography in suspected venous thrombosis by impedance plethysmography and 125I-fibrinogen leg scanning: a less invasive approach
Description
Noninvasive diagnostic testing is gaining acceptance in the evaluation of patients with clinically suspected venous thrombosis. A prospective study of 322 symptomatic patients has been done to ascertain the safety of replacing venography with impedance plethysmography and leg scanning. To provide a diagnostic reference, we did venography in all patients but withheld anticoagulants if the noninvasive tests were negative irrespective of the results of venography. None of the 163 patients with negative noninvasive tests died or developed clinical pulmonary embolism during 3 months follow-up confirming the safety of this approach. The positive predictive values indicate that therapeutic decisions can be based on a positive noninvasive outcome in patients without clinical disorders known to produce false-positive results
Additional details
Publishing Information
- Journal Title
- Ann. Intern. Med.
- Journal Volume
- 94
- Journal Issue
- 1
- Series
- Ann. Intern. Med.
- Journal Page Range
- 12-15
- ISSN
- 0003-4819
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 13669034
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; BLOOD FLOW; DIAGNOSIS; FIBRINOGEN; IODINE 125; LEGS; PATIENTS; RADIOISOTOPE SCANNING; THROMBOSIS
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BLOOD COAGULATION FACTORS; BODY; BODY AREAS; CARDIOVASCULAR DISEASES; COUNTING TECHNIQUES; DAYS LIVING RADIOISOTOPES; DIAGNOSTIC TECHNIQUES; DISEASES; ELECTRON CAPTURE RADIOISOTOPES; GLOBULINS; INTERMEDIATE MASS NUCLEI; IODINE ISOTOPES; ISOTOPES; LIMBS; MEDICINE; NUCLEI; ODD-EVEN NUCLEI; ORGANIC COMPOUNDS; PROTEINS; RADIOISOTOPES