Published January 1981 | Version v1
Journal article

Replacement of venography in suspected venous thrombosis by impedance plethysmography and 125I-fibrinogen leg scanning: a less invasive approach

Description

Noninvasive diagnostic testing is gaining acceptance in the evaluation of patients with clinically suspected venous thrombosis. A prospective study of 322 symptomatic patients has been done to ascertain the safety of replacing venography with impedance plethysmography and leg scanning. To provide a diagnostic reference, we did venography in all patients but withheld anticoagulants if the noninvasive tests were negative irrespective of the results of venography. None of the 163 patients with negative noninvasive tests died or developed clinical pulmonary embolism during 3 months follow-up confirming the safety of this approach. The positive predictive values indicate that therapeutic decisions can be based on a positive noninvasive outcome in patients without clinical disorders known to produce false-positive results

Additional details

Publishing Information

Journal Title
Ann. Intern. Med.
Journal Volume
94
Journal Issue
1
Series
Ann. Intern. Med.
Journal Page Range
12-15
ISSN
0003-4819