Dose Metrology: TLD/OSL Dose Accuracy and Energy Response Performance
- 1. University Ibn Tofail (Morocco)
- 2. Abdelmalek Essaadi University (Morocco)
- 3. National School of Architecture of Marrakech (Morocco)
Description
Performance evaluation and comparison in terms of measured dose accuracy, energy response, and coefficient of variation between two types of passive radiation dosimeters, thermoluminescent (TLD) and optically stimulated luminescence (OSL), used by workers in environments using ionizing radiation, for individual radiological monitoring and control of external exposure at different times (cumulative dose for 1 month), is a very important step to judge the quality and to identify the dosimetric aspects of TLD/OSL passive dosimeters and it is in this perspective that this study has been carried out. In fact this performance study consists in determining both the accuracy of the dose measurement R(10) and R(0.07) which is considered as the ratio of the measured dose (Hp(10) or Hp(0.07)) to the delivered dose (Hp(10) or Hp(0.07)) for each photon energy, the validity of the results of this test is based on the acceptance limits of the ICPR and the international standard ISO 62387, the relative energy response which is used to calculate the ratio of measured Hp(10) to delivered Hp(10), and Hp(0. 07) measured/Hp(0.07) normalized to 662 keV (Cs-137) energy to find which energy response is closest to the ideal case, and the coefficient of variation that allows to determine determine the statistical fluctuation of the doses found Hp(10)and Hp(0.07).
Additional details
Identifiers
Publishing Information
- Imprint Title
- International Conference on Occupational Radiation Protection #En Dash# Strengthening Radiation Protection of Workers #En Dash# Twenty Years of Progress and the Way Forward. Abstracts and Posters
- Imprint Pagination
- 249 p.
- Journal Page Range
- p. 178
- Report number
- IAEA-CN--300
Conference
- Title
- International Conference on Occupational Radiation Protection - Strengthening Radiation Protection of Workers - Twenty Years of Progress and the Way Forward
- Dates
- 5-9 Sep 2022
- Place
- Geneva (Switzerland)
INIS
- Country of Publication
- International Atomic Energy Agency (IAEA)
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 54049439
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ACCURACY; CESIUM 137; DOSEMETERS; IONIZING RADIATIONS; LUMINESCENCE; METROLOGY; OCCUPATIONAL EXPOSURE; PERSONNEL DOSIMETRY; PERSONNEL MONITORING; RADIATION DOSES; RADIATION PROTECTION; SAFETY STANDARDS
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CESIUM ISOTOPES; DOSES; DOSIMETRY; EMISSION; INTERMEDIATE MASS NUCLEI; ISOTOPES; MEASURING INSTRUMENTS; MONITORING; NUCLEI; ODD-EVEN NUCLEI; PHOTON EMISSION; RADIATION MONITORING; RADIATIONS; RADIOISOTOPES; STANDARDS; YEARS LIVING RADIOISOTOPES