Description

Results from a test with a lead-copper calorimeter in liquid argon are presented. The electromagnetic energy resolution obtained is 10%/√E. For hadronic showers the software weighting technique is demonstrated to work. A hadronic energy resolution of 50%/√E is found. (orig.)