A 1.5--4 Kelvin detachable cold-sample transfer system: Application to inertially confined fusion with spin-polarized hydrogens fuels

Description

A compact cold-transfer apparatus for engaging and retrieving samples at liquid helium temperatures (1.5--4K), maintaining the samples at such temperatures for periods of hours, and subsequently inserting them in diverse apparatuses followed by disengagement, is described. The properties of several thermal radiation-insulating shrouds, necessary for very low sample temperatures, are presented. The immediate intended application is transportable target-shells containing highly spin-polarized deuterons in solid HD or D2 for inertially confined fusion (ICF) experiments. The system is also valuable for unpolarized high-density fusion fuels, as well as for other applications which are discussed. 9 refs., 6 figs

Availability note (English)

MF available from INIS under the Report Number; OSTI as DE91007763; NTIS; INIS; US Govt. Printing Office Dep.

Files

22040069.pdf

Files (2.1 MB)

Name Size Download all
md5:b21441f4d210c368afb8e6073a55c0ba
2.1 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
32 p.
Report number
DOE/ER/18862--2

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
22040069
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Descriptors DEI
EQUIPMENT; HYDROGEN; INERTIAL CONFINEMENT; MASS TRANSFER; SHIELDING; SOLIDIFICATION; SPIN ORIENTATION; TESTING; THERMAL INSULATION; THERMONUCLEAR FUELS; ULTRALOW TEMPERATURE
Descriptors DEC
CONFINEMENT; ELEMENTS; FUELS; NONMETALS; ORIENTATION; PLASMA CONFINEMENT

Optional Information