Published January 2013
| Version v1
Journal article
Feasibility study on coded imaging of radiography X source spot
Creators
- 1. Institute of Applied Physics and Computational Mathematics, Beijing (China)
- 2. Postgraduate Department of China Academy of Engineering Physics, Beijing (China)
Description
Shape and intensity distribution of X source spot are required for radiography image inversion, which need high accuracy. With the image experiment, information of source size, shape and intensity distribution can be reconstructed from the coded imaging of Gauss beam containing noise with accuracy of 5%. With direct simulation by Monte Carlo program, information of source intensity distribution was reconstructed from coded imaging of the source containing scattering interference, energy and angular distribution. Coded imaging method can be used for detecting X source spot feature at the same time of radiography image, which is advantaged to improve inversion accuracy of radiography image. (authors)
Additional details
Publishing Information
- Journal Title
- Atomic Energy Science and Technology
- Journal Volume
- 47
- Journal Issue
- 1
- Journal Page Range
- p. 120-124
- ISSN
- 1000-6931
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 46131945
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ACCURACY; ANGULAR DISTRIBUTION; BEAMS; FEASIBILITY STUDIES; IMAGES; INDUSTRIAL RADIOGRAPHY; INFORMATION; INTERFERENCE; MONTE CARLO METHOD; SCATTERING; SHAPE; SIMULATION; X-RAY SOURCES
- Descriptors DEC
- CALCULATION METHODS; DISTRIBUTION; MATERIALS TESTING; NONDESTRUCTIVE TESTING; RADIATION SOURCES; TESTING
Optional Information
- Notes
- 7 figs., 10 refs.