Design of power measurement system for LHCD on HL-2A tokamak

  • 1. Southwestern Institute of Physics, Chengdu (China)

Description

A new linear power measurement system composed of logarithmic detectors is designed for LHCD system, which can solve the problems of narrow input power dynamic range and nonlinearity of the power measurement detectors. The measured results indicate that the characteristic curve of new system has a wide dynamic range of power measurement and high linearity. The dynamic input power range is greater than 40dB when the logarithmic consistency error is from -1dB to +1dB. The correlation coefficient of >0.999 is achieved in serviceable ranges using linear fitting. These results are better than previous equipment's. (authors)