Published June 2015
| Version v1
Journal article
Design of power measurement system for LHCD on HL-2A tokamak
Creators
- 1. Southwestern Institute of Physics, Chengdu (China)
Description
A new linear power measurement system composed of logarithmic detectors is designed for LHCD system, which can solve the problems of narrow input power dynamic range and nonlinearity of the power measurement detectors. The measured results indicate that the characteristic curve of new system has a wide dynamic range of power measurement and high linearity. The dynamic input power range is greater than 40dB when the logarithmic consistency error is from -1dB to +1dB. The correlation coefficient of >0.999 is achieved in serviceable ranges using linear fitting. These results are better than previous equipment's. (authors)
Additional details
Publishing Information
- Journal Title
- Nuclear Fusion and Plasma Physics
- Journal Volume
- 35
- Journal Issue
- 2
- Journal Page Range
- p. 109-113
- ISSN
- 0254-6086
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 51032865
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- DESIGN; EQUIPMENT; ERRORS; HL-2A TOKAMAK; LOWER HYBRID CURRENT DRIVE; MICROWAVE RADIATION; NONLINEAR PROBLEMS; POWER RANGE
- Descriptors DEC
- CLOSED PLASMA DEVICES; ELECTROMAGNETIC RADIATION; NON-INDUCTIVE CURRENT DRIVE; RADIATIONS; THERMONUCLEAR DEVICES; TOKAMAK DEVICES
Optional Information
- Notes
- 7 figs., 1 tab., 9 refs.