Published November 1981 | Version v1
Report Restricted

Common cause failure and unavailability analysis of the McGuire Unit 2 Auxiliary Feedwater System

Description

This report documents the results of a qualitative common cause failure analysis (CCFA) of the Auxiliary Feedwater System of the McGuire Nuclear Station Unit 2 owned by Duke Power Company. The purpose of the analysis is to demonstrate the utility of a CCFA technique developed by EG and G Idaho. The unavailability of the AFWS was also calculated

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A04/MF A01 as DE82005715.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
72 p.
Report number
EGG-IS--5545