Published November 1981
| Version v1
Report
Restricted
Common cause failure and unavailability analysis of the McGuire Unit 2 Auxiliary Feedwater System
Description
This report documents the results of a qualitative common cause failure analysis (CCFA) of the Auxiliary Feedwater System of the McGuire Nuclear Station Unit 2 owned by Duke Power Company. The purpose of the analysis is to demonstrate the utility of a CCFA technique developed by EG and G Idaho. The unavailability of the AFWS was also calculated
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A04/MF A01 as DE82005715.
Files
Additional details
Publishing Information
- Imprint Pagination
- 72 p.
- Report number
- EGG-IS--5545
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14725001
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- AUXILIARY WATER SYSTEMS; FAILURES; FAULT TREE ANALYSIS; FEEDWATER; MC GUIRE-2 REACTOR
- Descriptors DEC
- HYDROGEN COMPOUNDS; OXYGEN COMPOUNDS; POWER REACTORS; PWR TYPE REACTORS; REACTORS; SYSTEM FAILURE ANALYSIS; SYSTEMS ANALYSIS; WATER; WATER COOLED REACTORS; WATER MODERATED REACTORS