Published May 10, 1995 | Version v1
Report Open

Tank 241-C-111 vapor sampling and analysis tank characterization report

Description

Tank C-111 headspace gas and vapor samples were collected and analyzed to help determine the potential risks to tank farm workers due to fugitive emissions from the tank. Results presented here represent the best available data on the headspace constituents of Tank C-111. Almost all of the data in this report was obtained from samples collected on September 13, 1994.Data from 2 other sets of samples, collected on August 10, 1993 and June 20, 1994, are in generally good agreement with the more recent data. The tank headspace temperature was determined to be 27 C. Air from the Tank C-111 headspace was withdrawn via a 7.9 m-long heated sampling probe mounted in riser 6, and transferred via heated tubing to the VSS sampling manifold. All heated zones of the VSS were maintained at approximately 50 C. Sampling media were prepared and analyzed by WHC, Oak Ridge National Laboratories, Pacific Northwest Laboratories, and Oregon Graduate Institute of Science and Technology through a contract with Sandia National Laboratories. The 39 tank air samples and 2 ambient air control samples collected are listed in Table X-1 by analytical laboratory. Table X-1 also lists the 14 trip blanks provided by the laboratories. Tank C-111 is a single shell tank which received first-cycle decontamination waste from B Plant and was later used as a settling tank

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE95012593; NTIS; US Govt. Printing Office Dep.

Files

26074371.pdf

Files (596.0 kB)

Name Size Download all
md5:d0803c60b4e8a6b27b7df04ab27b22eb
596.0 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
16 p.
Report number
WHC-SD--WM-ER-425

Optional Information

Contract/Grant/Project number
Contract AC06-87RL10930
Funding organization
USDOE, Washington, DC (United States).