MAGNETIC MEASUREMENT SYSTEM FOR THE NSLS SUPERCONDUCTING UNDULATOR VERTICAL TEST FACILITY

Description

One of the challenges of small-gap superconducting undulators is measurement of magnetic fields within the cold bore to characterize the device performance and to determine magnetic field errors for correction or shimming, as is done for room-temperature undulators. Both detailed field maps and integrated field measurements are required. This paper describes a 6-element, cryogenic Hall probe field mapper for the NSLS superconducting undulator Vertical Test Facility (VTF) [1]. The probe is designed to work in an aperture only 3 mm high. A pulsed-wire insert is also being developed, for visualization of the trajectory, for locating steering errors and for determining integrated multi-pole errors. The pulsed-wire insert will be interchangeable with the Hall probe mapper. The VTF and the magnetic measurement systems can accommodate undulators up to 0.4 m in length

Availability note (English)

Available from PURL: https://www.osti.gov/servlets/purl/15016176-xspI5f/native/

Additional details

Publishing Information

Imprint Pagination
5 p.
Report number
BNL--73985-2005-CP

Conference

Title
Particle Accelerator Conference PAC 2005
Dates
16-20 May 2005
Place
Knoxville, TN (United States)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
36058774
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ACCELERATORS; APERTURES; CRYOGENICS; MAGNETIC FIELDS; PERFORMANCE; PROBES; WIGGLER MAGNETS
Descriptors DEC
EQUIPMENT; MAGNETS; OPENINGS

Optional Information

Contract/Grant/Project number
KC--0204011; AC--02-98CH10886
Funding organization