Defining an optimum pumping-time requirement for sampling ground-water wells on the Hanford site
Description
The objective was to determine the optimum time period necessary to pump water from a well before a representative sample of the ground water can be obtained. It was assumed that a representative sample has been collected if the concentration of chemical parameters is the same in a number of samples taken consecutively, so that the concentration of parameters does not vary with time of collection. Ground-water samples used in this project were obtained by pumping selected wells on the Hanford Site. At each well, samples were taken at two minute intervals, and on each sample various chemical analyses were performed. Samples were checked for pH, sulfate, iron, specific conductivity, chloride, nitrate and alkalinity. The data showed that pH, alkalinity, sulfate and specific conductivity levels stabilized almost immediately after pumping of the well began. In many wells, the chloride and nitrate levels were unstable throughout the 38-minute sampling period. Iron levels, however, did not behave in either fashion. The concentration of iron in the samples was high when pumping began but dropped rapidly as pumping continued. The best explanation for this is that iron is flushed from the sides of the casing into the well when pumping begins. After several minutes of pumping, most of the dissolved iron is washed from the well casing and the iron concentration reaches a stable plateau representative of the iron concentration in the ground water.Since iron concentration takes longest to stabilize, the optimum pumping time for a well is based on the iron stabilization time for that well
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01 as DE82015036.Files
14724118.pdf
Files
(504.7 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:d5179c32daf17a07e6579b8b0a284dcb
|
504.7 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 37 p.
- Report number
- PNL--4192
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14724118
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S58: GEOSCIENCES;
- Descriptors DEI
- GROUND WATER; HANFORD RESERVATION; OPTIMIZATION; PUMPS; SAMPLING; TIME DEPENDENCE; WATER CHEMISTRY; WELLS
- Descriptors DEC
- EQUIPMENT; HYDROGEN COMPOUNDS; OXYGEN COMPOUNDS; WATER; WATER TREATMENT