Published 1972 | Version v1
Report Restricted

RODDRP - A FORTRAN program for use in control rod calibration by the rod drop method

Creators

  • 1. Washington State University (United States)

Description

The different methods to measure reactivity which are applicable to control rod calibration are discussed. They include: 1) the positive period method, 2) the rod drop method, 3) the source-jerk method, 4) the rod oscillation method, and 5) the pulsed neutron method. The instrument setup used at WSU for rod drop measurements is presented. To speed up the analysis of power fall-off trace, a FORTRAN IV program called RODDRP was written to simultaneously solve the in-hour equation and relative neutron flux. The procedure for calculating the worth of the rod that produced the power trace is given. The reactivity for each time relative flux point is obtained. Conclusions about the status of the equipment are made

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Part of:
2. TRIGA owners' conference. Papers and abstracts

Additional details

Publishing Information

Imprint Title
2. TRIGA owners' conference. Papers and abstracts
Imprint Pagination
178 p.
Journal Page Range
p. 3.1-3.9
Report number
INIS-US--09N0217

Conference

Title
2. TRIGA owners' conference
Dates
21-22 Feb 1972
Place
College Station, TX (United States)

Optional Information

Notes
6 refs, 2 figs
Secondary number(s)
T--739